Fire protection for data centers and technical rooms

Fire separations and penetrations around critical IT infrastructure, executed without downtime.

Certified in accordance with
VCA-certified ISO 9001 Kiwa K21050
Trusted by, among others, DNB · WTC Amsterdam · Cooltower · ASML

A data center is full of fire separations that are continuously breached: busbars, cooling pipes, fiber-optic bundles, and cable trays constantly cross the walls between the data hall, MER, SER, and UPS rooms. Every non-certified penetration weakens the compartmentalization on which the entire safety strategy rests.

We work in data centers with change management, escorts, and tightly defined work windows. Our installers are accustomed to cleanroom-like discipline and to documenting every seal on drawings, so that facility management and the auditor always have a complete picture.

Where things go wrong

Risks relevant to this sector

High penetration density

Nowhere do as many cables and pipes pass through fire separations as in a data center. Without a tight registration system, within a year it becomes impossible to keep track of what has and hasn't been sealed.

Continuous changes

New clients, new racks, new power supply: there is constant construction. Fire-resistant sealing must be part of every change ticket, not an annual catch-up project.

Steel structure and cooling

Unprotected steel and technical mezzanines quickly lose their load-bearing capacity in a fire. Fire-resistant cladding keeps the structure standing for the required duration.

Our approach

Services that make the biggest difference here

Fire-Resistant Se­seals

Certified sealing of cable, pipe, and duct penetrations so that fire and smoke compartments remain intact.

More about this service

Fire-Resistant Steel­cladding

Protect the load-bearing capacity of your steel structure for up to 120 minutes in a fire, without compromising the design.

More about this service

Fire-Resistant Separ­structures

Walls, ceilings, and flame barriers that divide your building into safe, manageable fire compartments.

More about this service

Fire dampers

Automatic fire dampers in your ventilation system prevent fire and smoke from spreading through the ducts.

More about this service

Maintenance & Inspection

Periodic inspection and maintenance keep your fire protection provisions demonstrably in order.

More about this service
Practical example

What that looks like in practice

For a colocation data center, we set up an ongoing sealing program: every change involving a new penetration is certified and sealed within five business days and updated on the digital floor plan.

View our projects

Assessment framework

  • NEN-EN 1366-3 - fire resistance of penetrations
  • NEN 6068 - determination of the WBDBO
  • NEN-EN 13381 - fire resistance of structural steel components
Frequently asked questions

Questions about fire safety in data centers

Often yes: many penetrations are in the MER, SER or on the corridor side of the wall. Where the hall does need to be entered, this happens under escort within an agreed time window.

Every penetration receives a unique number, linked to a position on the floor plan. New penetrations are added as a separate line, with photo and certificate.

Yes, via a connection to your ticketing system or a dedicated request form, so that fire-resistant sealing is a standard part of every physical change.