Fire-resistant walls, ceilings and compartmentation

Fire-resistant walls, partition systems and ceilings that divide your building into manageable fire compartments.

Certified in accordance with
VCA-certified ISO 9001 Kiwa K21050
Trusted by, among others, DNB · WTC Amsterdam · Cooltower · ASML

Compartmentation is the basis of passive fire safety: by dividing a building into fire compartments and fire sub-compartments, a fire stays confined to where it started for longer.

We build and repair fire-resistant walls and ceilings: plasterboard partition systems, fire walls, suspended fire-resistant ceilings, flame barriers and fire-resistant wall cladding. In new build we work from the compartmentation drawing, in existing buildings from what is there - including adapting a layout that no longer fits after a conversion.

A large part of the work is fire-resistant boxing-in: shafts, beam junctions, ceiling edges and the awkward details where a wall meets a roof, a duct or a steel section. That is where compartmentation fails in practice, not in the middle of a wall. We work out those junction details in accordance with the system's test report, so the fire resistance rating holds across the whole separation and not just on paper.

What you can expect

  • Fire-resistant walls, partition systems, fire walls and ceilings
  • Fire-resistant boxing-in of shafts, edges and junction details
  • Flame barriers against the ceiling to prevent breakthrough
  • Fire-resistant wall cladding where existing walls do not comply
  • New construction and modification of existing compartmentalization

Applications

Fire-resistant walls and partition systems Fire-resistant ceilings Shafts and junction details Office buildings Healthcare institutions Shopping centers Industrial halls Parking garages Data centers

Standards & certification

  • NEN 6068 and NEN 6069
  • NEN-EN 1364 - non-loadbearing separating structures

Our team works VCA-certified and our organization is ISO 9001 and Kiwa (K21050) certified.

More about our certifications
Costs

What do fire-resistant separating structures cost?

Fire-resistant walls and ceilings are quoted per m2, depending on the construction (single or double boarded, insulation), the height, the required WBDBO, and the number of connection details and penetrations. Working at height and connecting to an existing, irregular structure increases the price. Flame barriers are relatively affordable per linear meter.

Common mistakes

  • Not extending a wall or flame barrier all the way to the floor above or the roof, leaving an open space above the ceiling.
  • Only addressing penetrations and connection details afterward, once the finishing is already complete.
  • Applying insulation or boarding that deviates from the tested construction.
Our approach

This is how we approach it

Survey & quote

We map out the situation and provide a detailed quote with scope and schedule.

Certified execution

Our VCA team carries out the work in accordance with applicable NEN standards, with minimal disruption.

Delivery & logbook

You receive a delivery file and digital logbook, and a maintenance contract if desired.

View our full process
Frequently asked questions

Questions about fire-resistant separating structures

That depends on the required fire resistance (30, 60, 90 or 120 minutes), the wall type and above all on the amount of detailing. A straight partition-system wall in an empty shell is considerably cheaper per square metre than the same wall in a building full of pipes, ducts and steel sections, where every junction detail has to be worked out separately.

Closing off shafts, ceiling edges, beam and column junctions and every place where a separation does not run flat, in a fire-resistant way. It is often the final piece of a compartmentation: the walls are up, but without correctly boxed-in details the fire resistance rating cannot be demonstrated.

Yes. After a conversion or a new layout, the original compartmentation often no longer fits. We assess the existing separations, indicate what must be added or repaired, and carry that out.

A vertical baffle, usually mounted against the ceiling, that delays the horizontal spread of smoke and flames beneath a ceiling.

Yes, via the consultation and assessment service - often the first step in a project.

Also of interest

Related services

Consultancy & Assessment

From a quick fire safety scan to a full survey: we map out the fire safety of your building clearly.

More about consultancy & assessment

Maintenance & Inspection

Periodic maintenance and inspection of your fire protection, with everything verifiably recorded in a digital logbook.

More about maintenance & inspection

Fire-Resistant Seals­

Sealing penetrations against fire with collars, wrap strips, sealant, mortar or other systems with a substantiated application, so that the WBDBO of your fire separation stays intact.

More about fire-resistant seals

Active in: Noord-Brabant · Eindhoven · Rotterdam and more

Ready to make your building fire-safe?

Request a no-obligation quote or schedule a consultation with one of our specialists.

Request a quote
Call now Request a quote

May we use analytics cookies? With your consent, we use Google Analytics to measure how the website is used, so that we can improve it. Functional storage the website needs is always on. Read our cookie policy for more information.