Fire-resistant doors and frames

Fire doors made to measure, adjusted or refurbished: up to 60 minutes fire resistance, smoke-resistant where required, self-closing and certified.

Certified in accordance with
VCA-certified ISO 9001 Kiwa K21050
Trusted by, among others, DNB · WTC Amsterdam · Cooltower · ASML

Fire-resistant doors are an essential part of every escape route. They ensure that fire and smoke spread more slowly between compartments, giving people fleeing a safe route for longer.

We supply and install bespoke fire doors and frames: single and double doors, glass doors, doors in existing frames and complete door and frame combinations for new construction. Every bespoke fire door is fitted with a self-closing closer, the right smoke seals and certified hardware, because the classification applies to the complete door set of door, frame and hardware, within the classification's field of application.

Replacement is often unnecessary. An existing fire door that no longer closes properly can usually be refurbished: adjusting the closer, replacing sealing profiles and drop-down seals, renewing the ironmongery. That costs a fraction of a new door and makes the door demonstrably sound again. We assess during the survey what makes sense in your situation.

What you can expect

  • Bespoke fire doors: single, double, glass door or complete door-and-frame assembly
  • Fire resistance of 30 or 60 minutes, with or without smoke resistance (Sa or S200)
  • Self-closing door closers in accordance with escape route requirements
  • Refurbishing and adjusting existing fire doors as an alternative to replacement
  • Maintenance of fire doors, recorded in your logbook

Applications

Stairwells Office corridors Technical rooms Parking garages Healthcare institutions Educational buildings

Standards & certification

  • NEN-EN 1634-1 and 1634-3 - testing of fire resistance and smoke leakage of doors
  • NEN-EN 13501-2 - classification (EI, Sa, S200, C)
  • NEN 6068 - WBDBO determination

Our team works VCA-certified and our organization is ISO 9001 and Kiwa (K21050) certified.

More about our certifications
Costs

What do fire-resistant doors cost?

The cost of a fire-resistant door depends on the size, the classification (30 or 60 minutes, with or without smoke resistance), the hardware, the finish, and whether the frame is replaced or reused. Standard interior doors are more affordable than wide or double doors and glass doors. Adjusting or refurbishing existing doors is often a fraction of the replacement price.

Common mistakes

  • Adjusting the closer so the door no longer latches fully shut; a fire door that doesn't close properly doesn't work.
  • Using gap retainers or wedges that keep the door permanently open.
  • Installing grilles or cat flaps in a fire door yourself, which voids the classification.

For contractors and installers: Fire protection in apartment buildings. Or submit a project request directly.

Our approach

This is how we approach it

Survey & quote

We map out the situation and provide a detailed quote with scope and schedule.

Certified execution

Our VCA team carries out the work in accordance with applicable NEN standards, with minimal disruption.

Delivery & logbook

You receive a delivery file and digital logbook, and a maintenance contract if desired.

View our full process
Frequently asked questions

Questions about fire-resistant doors

That depends on the dimensions, the classification (30 or 60 minutes, with or without smoke resistance), the ironmongery, the finish and whether the frame is replaced or reused. Standard internal doors are considerably cheaper than wide or double doors and glass doors. Also weigh up the refurbishment option: adjusting and re-sealing an existing door is often a fraction of the replacement price.

Usually, yes. If the door leaf and frame are structurally sound, the door can be overhauled: adjust the closer, replace seals and drop seal, renew hardware. Replacement is needed if the door leaf is damaged or warped, or if even after further investigation it cannot be established which door set is fitted.

Often, for example in escape routes: in addition to fire resistance, a smoke resistance requirement then applies, with a classification of Sa or S200 for the door. Fire resistance and smoke leakage are tested separately. Which requirement applies is assessed per situation.

Only if the frame itself also meets the requirements or can be made suitable. This is assessed during the inspection.

There is no fixed statutory interval. Take the manufacturer's instructions and the use as the starting point: an annual check of closing, seals and hardware is common, more often with intensive use. We carry this out under a maintenance contract and record every check, so that you can show during an inspection that the doors work.

Also of interest

Related services

Fire dampers

Installing, testing and maintaining fire dampers: automatic shut-off of ventilation ducts at every compartment boundary.

More about fire dampers

Fire-Resistant Separating Structures­

Fire-resistant walls, partition systems and ceilings that divide your building into manageable fire compartments.

More about fire-resistant separating structures

Consultancy & Assessment

From a quick fire safety scan to a full survey: we map out the fire safety of your building clearly.

More about consultancy & assessment

Active in: Den Haag · Rotterdam · Zuid-Holland · Utrecht · Amsterdam and more

Ready to make your building fire-safe?

Request a no-obligation quote or schedule a consultation with one of our specialists.

Request a quote
Call now Request a quote

May we use analytics cookies? With your consent, we use Google Analytics to measure how the website is used, so that we can improve it. Functional storage the website needs is always on. Read our cookie policy for more information.