Fire-resistant glass and fire-resistant glass partitions

Fire-resistant glass made to measure: glazed partitions, screens and glazing with EI 30 or EI 60 classification, supplied and installed.

Certified in accordance with
VCA-certified ISO 9001 Kiwa K21050
Trusted by, among others, DNB · WTC Amsterdam · Cooltower · ASML

Fire-resistant glass makes it possible to create fire compartments without boarding up a building. Stairwells, office partitions and escape routes stay light and clear, while fire and smoke cannot spread unhindered.

We supply and install bespoke fire-resistant glass: fire-resistant glazed partitions, screens, internal glazing, glass doors and fire-resistant roof windows. Every pane is made to measure for your situation, with an EI classification (integrity and thermal insulation) of 30 or 60 minutes. Smoke resistance is a separate performance, which we substantiate separately where needed.

If you are an architect or adviser working on a design, we are happy to help at the design stage. The classification of fire-resistant glazing applies within its field of application: the tested combination of glass, frame profile, glazing gaskets and fixing, with the permitted dimensions. Establishing this early prevents an attractive detail from later proving impossible to certify.

What you can expect

  • Fire-resistant glass made to measure: EI 30 or EI 60, calculated per pane
  • Glazed partitions, screens, internal glazing and glass doors
  • Fire-resistant roof windows and special applications
  • Preservation of natural light, transparency, and architectural appearance
  • Contributing during the design phase, so the tested combination stays feasible

Applications

Glazed partitions Screens and internal glazing Fire-resistant roof windows Offices Educational buildings Healthcare institutions Stairwells and escape routes

Standards & certification

  • NEN-EN 1364 / 1365 - fire resistance tests for separating structures
  • NEN-EN 13501-2 - classification E, EW and EI
  • NEN 6068 - WBDBO determination
  • NEN 6075 - determination of smoke passage

Our team works VCA-certified and our organization is ISO 9001 and Kiwa (K21050) certified.

More about our certifications
Costs

What does fire-resistant glass cost?

Fire-resistant glass is priced per m2 and depends heavily on the classification (EI 30 or EI 60), the dimensions of the panels, the frame system, and whether the existing frame can remain in place. Large, divisible panels and standard sizes are more cost-effective than custom on-site work. We quote inclusive of frame, glazing, and installation.

Common mistakes

  • Installing fire-resistant glass in a frame system that falls outside the classification's field of application.
  • Replacing glazing seals and hardware with non-certified parts during later maintenance.
  • Assuming that fire-resistant glass is also smoke-resistant or burglar-resistant without explicitly specifying this.
References

Where we have done this

Including at De Nederlandsche Bank, WTC Amsterdam, Cooltower Rotterdam and ASML Veldhoven - buildings where a rejected fire separation is not an option.

All projects
Our approach

This is how we approach it

Survey & quote

We map out the situation and provide a detailed quote with scope and schedule.

Certified execution

Our VCA team carries out the work in accordance with applicable NEN standards, with minimal disruption.

Delivery & logbook

You receive a delivery file and digital logbook, and a maintenance contract if desired.

View our full process
Frequently asked questions

Questions about fire-resistant glass

The number is the number of minutes the pane remains flame-tight (E) and thermally insulating (I). Which classification is needed follows from the requirement for the separation and the assessment criteria that go with it, not from a rule of thumb or a preference. EI 30 is, for example, common in office partitions and corridor walls, EI 60 in separations with a heavier requirement, such as some stairwells.

Yes, every pane is produced to measure. Each system does, however, have a maximum size for which the classification has been tested; large panes are therefore sometimes divided by a mullion. Standard sizes and divisible panes are considerably cheaper than bespoke work on site.

Yes, there are certified combinations that offer both fire resistance and thermal insulation.

Often yes, depending on the existing frame system - this is assessed during the inspection.

Not automatically. Fire resistance, burglar resistance and sound insulation are separate properties with their own classifications. Combination products exist, but they must be specified explicitly - do not assume that fire-resistant glass brings the other properties with it.

Also of interest

Related services

Fire-Resistant Doors

Fire doors made to measure, adjusted or refurbished: up to 60 minutes fire resistance, smoke-resistant where required, self-closing and certified.

More about fire-resistant doors

Fire dampers

Installing, testing and maintaining fire dampers: automatic shut-off of ventilation ducts at every compartment boundary.

More about fire dampers

Fire-Resistant Separating Structures­

Fire-resistant walls, partition systems and ceilings that divide your building into manageable fire compartments.

More about fire-resistant separating structures

Active in: Den Haag · Rotterdam · Zuid-Holland · Utrecht · Amsterdam and more

Ready to make your building fire-safe?

Request a no-obligation quote or schedule a consultation with one of our specialists.

Request a quote
Call now Request a quote

May we use analytics cookies? With your consent, we use Google Analytics to measure how the website is used, so that we can improve it. Functional storage the website needs is always on. Read our cookie policy for more information.